Baud Rate
Select from 1200, 2400, 4800, 9600, 19200, 38400,
57600 and 115200.
115200
Data Bits
Select from “7 and 8.
8
Flow Ctrl
Select from “None and Hardware.
None
Parity
Select from None, Odd, Even, Mark and Space.
None
Stop Bits
Select from “1 and 2.
1
Interval Timeout
This value allows gateway to packet the received data as a TCP/UDP
packet and sends it out even the size of them hasnt reached the
limit of Packet Length.
5
Packet Length
The limits size of the received data that gateway will packet as a
TCP/UDP packet.
Note: 0 is the same as the default value of TCP MSS, 1460.
0
Delimiter
The delimiter indicate gateway to packet the received data as a
TCP/UDP packet and sends it out even the size of them hasnt
reached the limit of Packet Length.
00
Delimiter Process
Select from “Do Nothing and Strip Delimiter.
Do Nothing
3.2.6 Basic